BJKVN - RC65 FLOURESCENT PENETRANT

  • MSDS: BJKVN
  • Manufacturer: SHERWIN INC
  • Product Name: RC65 FLOURESCENT PENETRANT
  • National Stock Number: 6850-01-267-4345
Product Identification

Product ID:RC65 FLOURESCENT PENETRANT
MSDS Date:01/06/1986
FSC:6850
NIIN:01-267-4345
MSDS Number: BJKVN

Responsible Party
SHERWIN INC
5530 BORWICK AVE
SOUTH GATE, CA 90280-7402
US

Emergency Phone: 213-861-6324

Info Phone: 213-861-6324

Cage: 21405

Contractor
SHERWIN INC.
SOUTH GATE, CA 90280-7402 US

Telephone: 562-861-6324/FAX 923-8370

Cage: 21405

Ingredients

ALIPHATIC OIL REFINED, HYDROTREATED MIDDLE DISTILLATE

Fraction By Weight: 50-70%


PHOSPHATE ESTER

Fraction By Weight: 15-25%


PHTHALATE ESTER

Fraction By Weight: 15-25%


FLUORESCENT DYE

Fraction By Weight: 1-7%

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:RESPIRATORY TRACT IRRITATION. CENTRAL
NERVOUS SYSTEM STIMULATION, FOLLOWED BY DEPRESSION IN VARYING
DEGREES.
Explanation of Carcinogenicity:THE COMPONENTS OF THIS PRODUCT HAVE NOT
SHOWN ANY EVIDENCE OF BEING CARCINOGENIC.
Effects of Overexposure:OVEREXPOSURE MAY LEAD TO RESPIRATORY
IRRITATION, NAUSEA, FATIGUE, DIZZINESS, HEADACHES, DERMATITIS AND
EYE IRRITATION.
Medical Cond Aggravated by Exposure:PERSONS WITH A SKIN DISORDER SHOULD
USE CAUTION WHEN HANDLING OR USING THIS PRODUCT.

First Aid

First Aid:SKIN: REMOVE CONTAMINATED CLOTHING. WASH WITH SOAP AND WATER.
GET MEDICAL ATTENTION IF IRRITATION PERSISTS. INHALATION: REMOVE TO
FRESH AIR & RESTORE BREATHING IF NECESSARY. GET MEDICAL ATTENTION.
EYE : IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES WHILE HOLDING
EYELIDS OPEN. GET MEDICAL ATTENTION. INGESTION: GET IMMEDIATE
MEDICAL ATTENTION. DO NOT INDUCE VOMITING. PREVENT ASPIRATION INTO
LUNGS.

Fire Fighting

Flash Point Method:CC
Flash Point:>200F,>93C
Autoignition Temp:Autoignition Temp Text:UNKNON
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS. DO NOT USE DIRECT
STREAM OF WATER WHICH CAN SPREAD THE FIRE. PRODUCT MAY FLOAT.

Accidental Release

Spill Release Procedures:MINOR: ABSORB MATERIAL WITH CLAY, VERMICULITE,
OR SIMILAR ABSORBENT MATERIAL. PLACE IN DISPOSAL CONTAINERS. MAJOR:
DIKE & CONTAIN SPILL. ELIMINATE SOURCES OF IGNITION. SHUT OFF
LEAKS. REMOVE LIQUID BY VACUUM OR ABSORBENT.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY, AREA AWAY FROM
SOURCES OF IGNITION. KEEP CONTAINERS CLOSED WHEN NOT IN USE. EMPTY
CONTAINERS CAN CONTAIN HAZARDOUS LIQUID/VAPOR.
Other Precautions:NONE

Exposure Controls

Respiratory Protection:IF VAPORS AND MISTS ARE GENERATED, USE
NIOSH/MSHA APPROVED RESPIRATOR TO PREVENT OVEREXPOSURE. CONSULT
RESPIRATOR MANUFACTURER TO DETERMINE APPROPRIATE TYPE EQUIPMENT FOR
GIVEN APPLICATION.
Ventilation:LOCAL EXHAUST RECOMMENDED. AVOID OPEN ELECTRICAL SOURCES
NEAR PRODUCT VAPOR AREAS.
Protective Gloves:CHEMICAL RESISTANT
Eye Protection:USE CHEMICAL SAFETY GOGGLES IF NEEDED.
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER.
Work Hygienic Practices:DO NOT TAKE INTERNALLY. AVOID SKIN CONTACT.
WASH SKIN AFTER USING PRODUCT. DO NOT EAT, DRINK OR SMOKE IN WORK
AREA.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:460F,238C
Evaporation Rate & Reference:<0.1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:YELLOW GREEN LIQUID, PETROLEUM ODOR
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:OPEN FLAMES AND MATERIALS AND HAZARDS
NORMALLY INCOMPATIBLE WITH PETROLEUM OILS.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE AND
OTHER HYDROCARBON COMPOUNDS DURING COMBUSTION.

Disposal

Waste Disposal Methods:WASTE MAY BE BURNED IN AN APPROVED INCINERATOR
OR DISPOSED OF IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE AND
FEDERAL LAWS AND REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.